Line Items: 0 Total Items: 0 Sub Total: $0.00 |
|
CURRENT
SHOPPING
CART STATUS
▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪▪
Applicable Tax and Freight Charge will be added to Final Invoice.
|
|
|
|
|
|
Oakton pH 800 pH/ORP Controller |
|
|
|
|
Select from three control modes: on/off,
proportional pulse length or proportional pulse frequency |
 |
- Large dual LCD shows both pH (or mV) and
temperature
- Two set point, two SPDT relay operation-
choose from lo/lo, lo/hi, hi/lo or hi/hi control
- Separate alarm relay
- 0 to 2000 second time delay adjustment on
all relays
- Separately adjustable high and low set
point hysteresis bands
- 0-20/4-20 mA transmitter/recorder output
- Push button two-point calibration
- On-line electrode offset adjustment
- Hold feature lets you connect flow or
level switches to protect your pump
- Two level password protection
- LED indicators signal control activities
- Battery back-up of memory
|
| |
|

OAKTON is proud to present the highly versatile
1000 series pH/ORP controller. Select from three control types. Use
on/off control to shut off your pump or valve when your process passes
its set points. Use pulse frequency or pulse length proportional control
to gradually increase or decrease your pump’s or valve’s response,
depending on the amount by which your process has passed the set point.
Customize your
controller to fit your exact application! This unit is selectable for pH or
ORP (as mV or percent) control; 0-20 or 4-20 mA scaleable, isolated recorder
output; normally open or closed relays; and manual or automatic temperature
compensation. Controller also features a safety Hold function, manual
override of the relays, and resistance to electrical signal input noise.

pH
1000 controller product bulletin |
| |
|
PRODUCT
SPECIFICATIONS

|
Measures: |
pH |
mV |
Temperature |
|
Range: |
0.00 to 14.00 pH |
±1000 mV |
-9.9 to 125°C |
|
Resolution: |
0.01 pH |
1 mV |
0.1°C |
|
Accuracy: |
±0.01 pH |
±1 mV |
±.1°C |
|
Calibration: |
one or two points (select
from pH 1.00, 4.01, 6.86, 7.00, 9.00, 9.18 or 10.00) |
mV Offset |
offset up to ±5°C |
|
Control: |
on/off |
|
Number of inputs: |
one |
|
Number of setpoints: |
two (high and low) |
|
Separate alarm relay: |
No |
|
Output Control: |
2 SPDT relays, 6A at 110 VAC |
|
Output Current: |
isolated 4-20 mA, 600 W maximum load |
|
Hysteresis: |
0.1 to 1.0 pH, 10 to 100 mV, or 1 to 10% |
| Relay
Delay: |
selectable, 0 to 2000 seconds |
| Input
Impedence: |
10^6 MW |
|
Electrical Isolation: |
yes, galvanically |
|
Temperature Sensor: |
100 W or 1000 W Pt RTD |
|
Temperature Compensation: |
Automatic or manual from -9.9 to 125°C |
|
Password Protection: |
two level password |
|
Display: |
dual line LCD, 4-digit upper and 3 1/2 digit lower |
|
Operating Temperature: |
-10 to 60°C |
|
Housing: |
1/4 DIN |
|
Dimensions: |
3.8" x 3.8" x 6.9" (9.6 x 9.6 x 17.5 cm) |
|
Shipping Weight: |
2.5 lbs (1.2 kg) |
|
| |
|
PURCHASE ORP CONTROLLERS
 |
|
ITEM NUMBER |
DESCRIPTION |
PRICE |
|
|
pH/ORP pH 800 Controller |
|
|
|
|