Line Items: 0
Total Items: 0
Sub Total: $0.00

CURRENT SHOPPING
CART STATUS

▪▪
Applicable Tax and Freight Charge will be added to Final Invoice.

Oakton pH 800 pH/ORP Controller
   

Select from three control modes: on/off, proportional pulse length or proportional pulse frequency

  • Large dual LCD shows both pH (or mV) and temperature
  • Two set point, two SPDT relay operation- choose from lo/lo, lo/hi, hi/lo or hi/hi control
  • Separate alarm relay
  • 0 to 2000 second time delay adjustment on all relays
  • Separately adjustable high and low set point hysteresis bands
  • 0-20/4-20 mA transmitter/recorder output
  • Push button two-point calibration
  • On-line electrode offset adjustment
  • Hold feature lets you connect flow or level switches to protect your pump
  • Two level password protection
  • LED indicators signal control activities
  • Battery back-up of memory
 


OAKTON is proud to present the highly versatile 1000 series pH/ORP controller. Select from three control types. Use on/off control to shut off your pump or valve when your process passes its set points. Use pulse frequency or pulse length proportional control to gradually increase or decrease your pump’s or valve’s response, depending on the amount by which your process has passed the set point.

Customize your controller to fit your exact application! This unit is selectable for pH or ORP (as mV or percent) control; 0-20 or 4-20 mA scaleable, isolated recorder output; normally open or closed relays; and manual or automatic temperature compensation. Controller also features a safety Hold function, manual override of the relays, and resistance to electrical signal input noise.


 pH 1000 controller product bulletin

 

PRODUCT SPECIFICATIONS

Measures: pH mV Temperature
Range: 0.00 to 14.00 pH ±1000 mV -9.9 to 125°C
Resolution: 0.01 pH 1 mV 0.1°C
Accuracy: ±0.01 pH ±1 mV ±.1°C
Calibration: one or two points (select from pH 1.00, 4.01, 6.86, 7.00, 9.00, 9.18 or 10.00) mV Offset offset up to ±5°C
Control: on/off
Number of inputs: one
Number of setpoints: two (high and low)
Separate alarm relay: No
Output Control: 2 SPDT relays, 6A at 110 VAC
Output Current: isolated 4-20 mA, 600 W maximum load
Hysteresis: 0.1 to 1.0 pH, 10 to 100 mV, or 1 to 10%
Relay Delay: selectable, 0 to 2000 seconds
Input Impedence: 10^6 MW
Electrical Isolation: yes, galvanically
Temperature Sensor: 100 W or 1000 W Pt RTD
Temperature Compensation: Automatic or manual from -9.9 to 125°C
Password Protection:

two level password

Display: dual line LCD, 4-digit upper and 3 1/2 digit lower
Operating Temperature: -10 to 60°C
Housing: 1/4 DIN
Dimensions: 3.8" x 3.8" x 6.9" (9.6 x 9.6 x 17.5 cm)
Shipping Weight: 2.5 lbs (1.2 kg)
 

PURCHASE ORP CONTROLLERS

ITEM NUMBER DESCRIPTION PRICE

QTY LWD5670500

pH/ORP pH 800 Controller
$431.00