Orion Ion Selective Electrodes

The photos below are examples of each type of Orion Ion-Selective Electrode. The design of the sensing element determines the sensitivity and selectivity for the ion of interest. Orion ISE's have been designed to provide you with the optimum in both performance and reliability.

Solid State Half-Cell
Chloride, Fluoride
Plastic Membrane Half-Cell
Nitrate
Gas Sensing Combination
Ammonia

Measurement by ion-selective electrode (ISE) is applicable in virtually every laboratory. Measure ion concentrations in such samples as water, food, pharmaceuticals, and biological samples. Analytical methods using ISE's have been developed and published throughout the world.

The main advantages of electrode technology are the variety of analytical methods available. Choice of measurement method improves accuracy and reproducibility of results. Direct calibration is the most commonly used electrode method. Sample concentration is directly read on a specific ion meter or from a calibration curve. Incremental methods increase the number of measurable species. With these methods, electrode calibration is unnecessary, making them useful when measuring complex samples. Electrodes can also be used as end point detectors in titrations.  

SAVE TIME AND MONEY

Electrode measurements are simpler and faster than other analytical techniques. Time-consuming sample preparation steps such as filtrations and distillations are rarely needed. Analysis time is typically under one minute.

A direct readout meter displaying concentration in units of your choice is the fastest, easiest ISE measurement system. Orion ISE/pH meters display concentration in units of your choice, completing the ISE measurement system. In comparison to other methods, such as AA or ion chromatography, the initial cost of setup is less and does not require additional expensive readout equipment. Methods are adaptable to both lab and field use. Sample color or turbidity does not affect the measurement. ISE's are inexpensive. Typically, the cost per test is only a few cents.

 

ION SELECTIVE ELECTRODE SPECIFICATIONS

Species Ammonia Chlorine Fluoride Nitrate
Order No. 9512BN 9770BN 9609BN 9707BN
Connector Type BNC BNC BNC BNC
Construction Gas Sensing Combination Solid State Combination ionplus Sure Flow Solid State Comb. ionplus Sure Flow Plastic Membrane Combination
Concentration Range 1.0 to 5 x 10-7 M
17,000 to 0.01 ppm
3 x 10-4 to 10-7 M
20 to 0.01 ppm
Saturated to 10-6 M
Saturated to 0.02 ppm
1.0 to 7 x 10-6 M
14,000 to 0.1 ppm as N
Optimum Temp. Range 0-50 C 0-50 C 0-80 C 0-40 C
Required Reference Cat. No. Included Included Included Included
Ref. Fill Soln. Cat. No. 951202 Inner None Required 900061 900046
Calibration Standards Cat. No. 0.1 M NH4Cl /
951006
100 ppm as Cl2 /
977007
0.1 M NaF /
940906
100 ppm F- /
940907
1 ppm F- with
TISAB II / 040906
2 ppm F- with
TISAB II / 040907
10 ppm F- with
TISAB II / 040908
0.1 M NaNO3 /
920706
1,000 ppm N /
920707
100 ppm N /
930707
Required ISA Cat. No. 951211 977010 /
Iodide Reagent
977011 /
Acid Reagent
940909 /
TISAB II
940911 /
TISAB
930711 or
930710 /
Nitrate ISS
 

PURCHASE ELECTRODES

ITEM NUMBER DESCRIPTION PRICE

QTY LTO9512BNWP

Orion Ammonia 9512BN Electrode
$595.00

QTY LTO9770BN

Orion Chlorine 9770BN Electrode
$548.00

QTY LTO9609BN

Orion Fluoride 9609BN Electrode
$692.00

QTY LTO9707BN

Orion Nitrate 9707BN Electrode
$808.00