The photos below are examples of each type
of Orion Ion-Selective Electrode. The design of the sensing element
determines the sensitivity and selectivity for the ion of interest.
Orion ISE's have been designed to provide you with the optimum in both
performance and reliability. |
Solid
State Half-Cell
Chloride, Fluoride |
Plastic Membrane Half-Cell
Nitrate |
Gas
Sensing Combination
Ammonia |
 |
 |
 |
|
Measurement by
ion-selective electrode (ISE) is applicable in virtually every
laboratory. Measure ion concentrations in such samples as water, food,
pharmaceuticals, and biological samples. Analytical methods using ISE's
have been developed and published throughout the world.
The main
advantages of electrode technology are the variety of analytical methods
available. Choice of measurement method improves accuracy and
reproducibility of results. Direct calibration is the most commonly used
electrode method. Sample concentration is directly read on a specific
ion meter or from a calibration curve. Incremental methods increase the
number of measurable species. With these methods, electrode calibration
is unnecessary, making them useful when measuring complex samples.
Electrodes can also be used as end point detectors in titrations.
|
|
SAVE
TIME AND MONEY

Electrode measurements are
simpler and faster than other analytical techniques. Time-consuming
sample preparation steps such as filtrations and distillations are
rarely needed. Analysis time is typically under one minute.
A direct readout
meter displaying concentration in units of your choice is the fastest,
easiest ISE measurement system.
Orion ISE/pH meters display
concentration in units of your choice, completing the ISE measurement
system. In comparison to other methods, such as AA or ion chromatography,
the initial cost of setup is less and does not require additional expensive
readout equipment. Methods are adaptable to both lab and field use. Sample
color or turbidity does not affect the measurement. ISE's are inexpensive.
Typically, the cost per test is only a few cents. |
| |
|
ION
SELECTIVE ELECTRODE SPECIFICATIONS

| Species |
Ammonia |
Chlorine |
Fluoride |
Nitrate |
| Order No. |
9512BN |
9770BN |
9609BN |
9707BN |
| Connector Type |
BNC |
BNC |
BNC |
BNC |
| Construction |
Gas Sensing
Combination |
Solid State
Combination |
ionplus
Sure Flow Solid State Comb. |
ionplus
Sure Flow Plastic Membrane Combination |
| Concentration Range |
1.0
to 5 x 10-7
M
17,000 to 0.01 ppm |
3 x
10-4 to 10-7 M
20 to 0.01 ppm |
Saturated to 10-6
M
Saturated to 0.02 ppm |
1.0
to 7 x 10-6
M
14,000 to 0.1 ppm as N |
| Optimum Temp. Range |
0-50 C |
0-50 C |
0-80 C |
0-40 C |
| Required Reference
Cat. No. |
Included |
Included |
Included |
Included |
| Ref. Fill Soln. Cat.
No. |
951202
Inner |
None
Required |
900061 |
900046 |
| Calibration
Standards Cat. No. |
0.1 M
NH4Cl /
951006 |
100
ppm as Cl2
/
977007 |
0.1 M
NaF /
940906
100 ppm F- /
940907
1 ppm F- with
TISAB II / 040906
2 ppm F- with
TISAB II / 040907
10 ppm F- with
TISAB II / 040908 |
0.1 M
NaNO3
/
920706
1,000 ppm N /
920707
100 ppm N /
930707 |
| Required ISA Cat.
No. |
951211 |
977010 /
Iodide Reagent
977011 /
Acid Reagent |
940909 /
TISAB II
940911 /
TISAB |
930711 or
930710 /
Nitrate ISS |
|
| |
|