SensIon7 Conductivity/TDS/Salinity Meter |
For accurate
conductivity analysis of water quality, salinity, TDS, and other
aqueous samples in the laboratory
|
|
 |
-
Fast response
-
Quick single point
calibration
-
All-in-one 5-pin
connector
-
Recalls /
downloads / prints data
-
Meter comes complete
with 4 pole conductivity probe (1 meter cable), 1000 µs/cm standard
and manual
-
Additional standards
sold separately below

sensION7 Meter Manual |
| |
|

Now you can take conductivity measurements in the lab with Hach's
benchtop sensION7 Conductivity Meter. This laboratory meter determines
conductivity, plus TDS, salinity, and temperature with just the push of
a button. You will never again have problems calibrating a conductivity
meter, no matter which range you're using to measure. The sensION7 comes
with a four-pole electrode, which covers the range of 0.1 µS/cm to 199.9
mS/cm. |
| |
|
PURCHASE SENSION7 METERS
 |
|
ITEM
NUMBER |
DESCRIPTION |
PRICE |
|
|
sensION7
Benchtop Conductivity Meter with electrode, 1-meter (40") cable, 115 V |
|
|
CONDUCTIVITY
STANDARDS
|
|
|
180 ± 10
µS/cm, 90 ± 5 mg/L TDS (85.47 mg/L as NaCl), 100 mL |
|
|
|
1000 ± 10
µS/cm, 500 ± 5 mg/L TDS (491 mg/L as NaCl), 100 mL |
|
|
|
1990 ± 20
µS/cm, 995 ± 5 mg/L TDS (1000 mg/L as NaCl), 100 mL |
|
|
|
18,000 ± 50
µS/cm, 9000 ± 25 mg/L TDS (10,246 mg/L as NaCl), 100 mL |
|
|
|
53,000 µS/cm,
35.0 ppt salinity, 500 mL |
|
|
OPTIONAL
ACCESSORIES
|
|
|
Four-pole
conductivity probe with 1-meter cable |
|
|
|
Four-pole
conductivity probe with 3-meter cable |
|
|
|
LIS chamber
(low ionic strength samples) |
|
|
|
HachLink™
software for computer interface |
|
|
|
Computer
serial cable |
|
|
|
|
|
SPECIFICATIONS

|
|
|
- Inputs
5-pin (with temperature), Line Power
- Outputs
One-way, RS-232
- Power Requirements
6-12 V dc; use either Hach-supplied 115 or 230 V, 50/60 Hz
external power supply or a customer-provided supply with 50 mA
output, 5.5 mm power plug with a 2.5 mm center post opening
- Installation Category
II
- Instrument Drift
<40µV/°C
- Input Bias Current
<±1 picoamp at 25°C; ±4 picoamp over full range
- Environmental Requirements
0 to 50°C at 85% noncondensing relative humidity
- Dimensions
25.4 x 15 x 8.37 cm (10.15 x 6 x 3.5")
- Enclosure
Water resistant (IP32), chemical resistant
*Subject to change without notice. |
|
|