The Man-Pan Manhole Inflow Protector
The Rigid And Easy To Remove Solution To Surface Flow Infiltration


SPECIFICATIONS

1. SCOPE

1.1 Contractor shall furnish MANHOLE INSERTS as called for in the specification.

1.2 The INSERT shall effectively reduce or prevent surface water inflow through manhole covers. The insert shall also prove effective in keeping grit, sand, salt, chemical spills, foreign objects, road oils, etc. from entering the collection system lines.

1.3 INSERT shall be manufactured specifically for use in collection system manholes.

2. MATERIAL AND DESIGN

2.1 The INSERT shall be manufactured from ABS material that meets ASTM D-4673 Specifications. This material is commonly found in waste water collection systems and has superior stress crack resistance, combined with a high impact strength and rigidity.

2.2 The premolded thickness of the INSERT shall be no less than 1/8" or greater than 3/16".

2.3 The INSERT shall be manufactured to meet the dimensions provided by the purchaser to allow easy installation within the manhole frame.

2.4 To enhance performance, the INSERT shall have a positive arch - "bubble top", not a negative arch - bowl or inverted dome. Drawings should be provided upon request.

3. INSTALLATION

3.1 The manhole rim shall be cleaned of all dirt and debris before placing the INSERT upon the rim.

3.2 The INSERT shall be fully seated around the manhole frame rim.

3.3 The manhole cover is replaced as before, and the installation is complete.

4. REMOVAL

4.1 The INSERT shall have (2) corrosion resistant lifting lugs molded into the insert for easy removal and re-installation into the manhole frame. The lifting lugs will be located 180 degrees apart and designed to be functional with a standard "J" hook.

5. GASKET

5.1 The INSERT shall have a closed cell neoprene gasket with adhesive backing, installed upon the insert rim by the manufacturer.

6. VENTING

6.1 If the valve option is elected by purchaser an INSERT will be supplied with a Tideflex® Relief/Check Valve installed in the center of the INSERT.

6.2 The Tideflex Relief/Check Valve shall have a 1.25" inside diameter, and shall be press-fit into center of INSERT with PVC bushing.

6.3 The Tideflex shall have a tapered, low-profile design.

6.4 The Tideflex shall be able to discharge 20 CFM during venting operation.

6.5 The Tideflex shall have a cracking pressure of 1/2" WC.

6.6 The Tideflex shall be a flexible and durable all-elastomer construction and shall be able to withstand field abuse without damage.

7. MEASUREMENT

7.1 The INSERT shall be manufactured to fit the manhole frame rim upon which the manhole cover rests. Exact measurements shall be required from the purchaser.

7.2 Instructions and measuring diagrams will be made available to the purchaser, to insure a proper fit of INSERT within the manhole frame.

8. ACCESS FOR TESTING OF AIR QUALITY

8.1 Optional, available upon request. Purchaser must designate, if required.